top of page

![]() | ![]() | ![]() |
|---|---|---|
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
|---|---|---|
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Work Gets Done When We're Around
Building Process
Construction Site Building Process
This slideshow shows the construction of a 36-by-36-foot building by L-Seven Construction. It highlights eight main stages of construction, from start to finish. While every building process is different and may involve additional steps or materials, these photos will give you an idea of what goes into this particular pole building.
Take a look at the photos and descriptions to see how the building comes together.
Construction Process Slideshow

Setting Lines
The first step is laying out the building. We set lines to establish reference points for accurate post placement. This first step is critical to ensuring the entire building is square, properly aligned, and correctly positioned on the site.

Digging Post Holes
Once the first step is complete, our team uses specialized equipment to dig the holes for the building's poles. These holes typically range from two to four feet in diameter, depending on the building's requirements.

Standing Posts
Once the holes are dug, our crew carefully raises and positions the pressure-treated posts that will support the building. Some posts exceed 36 feet in length, requiring careful handling and precise placement.

Aligning Posts and Pouring Concrete
Once the posts are positioned, temporary braces are installed to hold them in place.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.

Roof Framing
We use a transit, a leveling instrument, to mark a consistent level line on every post. From this line, we measure upward to determine the placement of the roof trusses and downward to establish the height of the concrete slab. This ensures the building is level from the foundation to the roof.

Framing Exterior Walls and Adding Roof Material
Next, we install CCB vapor barrier insulation beneath the metal roofing. This provides insulation while helping prevent condensation from forming on the underside of the roof metal.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.

Siding Exterior Walls
Because the front wall has large openings for overhead doors, the engineer requires additional structural reinforcement known as a shear wall. In this case, we used OSB for the shear wall. This reinforcement helps the building resist sideways forces from wind and earthquakes, providing greater structural stability.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.

Finalizing Building
CCB insulation is installed on the outside of the three remaining walls, followed by the metal siding.
We added wainscoting for an aesthetic look.
We added wainscoting for an aesthetic look.

Setting Lines
The first step is laying out the building. We set lines to establish reference points for accurate post placement. This first step is critical to ensuring the entire building is square, properly aligned, and correctly positioned on the site.

Digging Post Holes
Once the first step is complete, our team uses specialized equipment to dig the holes for the building's poles. These holes typically range from two to four feet in diameter, depending on the building's requirements.

Standing Posts
Once the holes are dug, our crew carefully raises and positions the pressure-treated posts that will support the building. Some posts exceed 36 feet in length, requiring careful handling and precise placement.

Aligning Posts and Pouring Concrete
Once the posts are positioned, temporary braces are installed to hold them in place.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.

Roof Framing
We use a transit, a leveling instrument, to mark a consistent level line on every post. From this line, we measure upward to determine the placement of the roof trusses and downward to establish the height of the concrete slab. This ensures the building is level from the foundation to the roof.

Framing Exterior Walls and Adding Roof Material
Next, we install CCB vapor barrier insulation beneath the metal roofing. This provides insulation while helping prevent condensation from forming on the underside of the roof metal.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.

Siding Exterior Walls
Because the front wall has large openings for overhead doors, the engineer requires additional structural reinforcement known as a shear wall. In this case, we used OSB for the shear wall. This reinforcement helps the building resist sideways forces from wind and earthquakes, providing greater structural stability.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.

Finalizing Building
CCB insulation is installed on the outside of the three remaining walls, followed by the metal siding.
We added wainscoting for an aesthetic look.
We added wainscoting for an aesthetic look.

Setting Lines
The first step is laying out the building. We set lines to establish reference points for accurate post placement. This first step is critical to ensuring the entire building is square, properly aligned, and correctly positioned on the site.

Digging Post Holes
Once the first step is complete, our team uses specialized equipment to dig the holes for the building's poles. These holes typically range from two to four feet in diameter, depending on the building's requirements.

Standing Posts
Once the holes are dug, our crew carefully raises and positions the pressure-treated posts that will support the building. Some posts exceed 36 feet in length, requiring careful handling and precise placement.

Aligning Posts and Pouring Concrete
Once the posts are positioned, temporary braces are installed to hold them in place.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.

Roof Framing
We use a transit, a leveling instrument, to mark a consistent level line on every post. From this line, we measure upward to determine the placement of the roof trusses and downward to establish the height of the concrete slab. This ensures the building is level from the foundation to the roof.

Framing Exterior Walls and Adding Roof Material
Next, we install CCB vapor barrier insulation beneath the metal roofing. This provides insulation while helping prevent condensation from forming on the underside of the roof metal.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.

Siding Exterior Walls
Because the front wall has large openings for overhead doors, the engineer requires additional structural reinforcement known as a shear wall. In this case, we used OSB for the shear wall. This reinforcement helps the building resist sideways forces from wind and earthquakes, providing greater structural stability.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.

Finalizing Building
CCB insulation is installed on the outside of the three remaining walls, followed by the metal siding.
We added wainscoting for an aesthetic look.
We added wainscoting for an aesthetic look.

Setting Lines
The first step is laying out the building. We set lines to establish reference points for accurate post placement. This first step is critical to ensuring the entire building is square, properly aligned, and correctly positioned on the site.

Digging Post Holes
Once the first step is complete, our team uses specialized equipment to dig the holes for the building's poles. These holes typically range from two to four feet in diameter, depending on the building's requirements.

Standing Posts
Once the holes are dug, our crew carefully raises and positions the pressure-treated posts that will support the building. Some posts exceed 36 feet in length, requiring careful handling and precise placement.

Aligning Posts and Pouring Concrete
Once the posts are positioned, temporary braces are installed to hold them in place.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.
When the concrete trucks arrive, we pour the required amount of concrete into each hole to securely anchor the posts in the ground.

Roof Framing
We use a transit, a leveling instrument, to mark a consistent level line on every post. From this line, we measure upward to determine the placement of the roof trusses and downward to establish the height of the concrete slab. This ensures the building is level from the foundation to the roof.

Framing Exterior Walls and Adding Roof Material
Next, we install CCB vapor barrier insulation beneath the metal roofing. This provides insulation while helping prevent condensation from forming on the underside of the roof metal.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.
Once the roof insulation is installed, we begin framing the walls using the commercial girt method, installing the boards horizontally to provide additional strength to the building.

Siding Exterior Walls
Because the front wall has large openings for overhead doors, the engineer requires additional structural reinforcement known as a shear wall. In this case, we used OSB for the shear wall. This reinforcement helps the building resist sideways forces from wind and earthquakes, providing greater structural stability.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.
Because the front wall contains an OSB shear wall, we install house wrap over the OSB to protect it from outside moisture while allowing water vapor to escape. This is particularly important if the customer decides to heat the building in the future.
Next, we install CCB insulation in the remaining walls to provide thermal insulation and help prevent condensation.

Finalizing Building
CCB insulation is installed on the outside of the three remaining walls, followed by the metal siding.
We added wainscoting for an aesthetic look.
We added wainscoting for an aesthetic look.
1/8
Methodologes
If you have any questions regarding our building process, or want to know more about us
bottom of page





























